Detection of demyelination in multiple sclerosis by analysis of T2* relaxation at 7 T

NeuroImage: Clinical, Volume 7, 2015, Pages 709-714

Abstract

Multiple sclerosis (MS) is a relatively common cause of inflammatory demyelinating lesions of the central nervous system. In an attempt to detect and characterize ongoing demyelination in MS patient brains, we used a novel magnetic resonance imaging (MRI) technique, involving the fitting of a three-component model to the stripin: si11.gif relaxation behavior at high-field (7 T). This model allowed estimation of the amount of myelin water (and thus indirectly myelin content), axonal water, and interstitial water. In this study, 25 relapsing–remitting MS patients underwent a 7 T MRI from which 12 gadolinium-enhancing lesions, 61 non-enhancing lesions, and their corresponding contralateral normal appearing white matter (NAWM) regions were analyzed. In both enhancing and non-enhancing lesions, the amplitude of myelin water was significantly decreased, and interstitial and axonal water were increased relative to the contralateral NAWM. Longer relaxation time stripin: si12.gif of interstitial and axonal water, and lower frequency shift of axonal water, were also observed in both enhancing and non-enhancing lesions when compared to the contralateral NAWM. No significant difference was found between enhancing lesions and non-enhancing lesions. These findings suggest that the fitting of a three-component model to the stripin: si13.gif decay curve in MS lesions may help to quantify myelin loss.

Highlights

 

  • We investigated the demyelination effects onT2* relaxation in a clinical MS cohort at 7 T.
  • 3-Component model of white matter is reproducible.
  • 3-Component model was demonstrated the feasibility to detect and potentially discriminate demyelination in MS.
  • The analysis of T2* relaxation may help to understand myelin pathology in MS.

Keywords: stripin: si14.gif relaxation, Water compartment, Multiple sclerosis, Demyelination.

1. Introduction

Multiple sclerosis (MS) is a chronic, inflammatory, demyelinating disease of the central nervous system characterized by the formation of focal demyelinated regions (‘plaques’ or ‘lesions’). For the last quarter century, magnetic resonance imaging (MRI) has been routinely used to help with the diagnosis of MS, as well as to monitor disease evolution and treatment efficacy. However, the mechanisms underlying the clinical progression of MS and the relationship of MRI findings to pathology (demyelination, axonal loss and neuronal degeneration) remain poorly understood. Meanwhile, numerous studies have attempted to more specifically assess the demyelination process occurring in MS by measuring indirectly the local myelin content using various MR techniques, such as diffusion tensor imaging, magnetization transfer (MT) imaging, and separation ofT2relaxation components ( Laule et al., 2007 ). The separation ofT2relaxation components has been used to measure the amount of water trapped between the myelin layers, which is generally considered to reflect brain myelin content. This is based on the fact that the diffusion-restricting properties of myelin lead to distinctT2values for water between the myelin layers (or myelin water), intra-axonal water, and interstitial water (or extracellular water), with the myelin water pool having the shortestT2( Lancaster et al., 2003 ; Laule et al., 2004 ; Andrews et al., 2005 ; MacKay et al., 2006 ). With this model in mind, these studies have tried to assess the relative concentration of myelin water using mathematical analyses of theT2relaxation decay curves acquired with a multi-spin-echo (mSE) technique. Strong correlation between the shortT2signal fraction and the anatomical distribution of myelin was found in postmortem MS brain samples ( Moore et al., 2000 ; Laule et al., 2006 ; Laule et al., 2008 ), supporting the notion that this fraction reflects myelin water. Absence of myelin water signal was also found in chronic demyelinated MS lesions ( Moore et al., 2000 ). The post mortem findings were further supported by in vivo studies that also reported decreased amount of myelin water in MS lesions ( MacKay et al., 1994 ; Vavasour et al., 1998 ; Laule et al., 2004 ).

More recently, multi-gradient-echo (mGRE) techniques have been proposed as another way to obtain cellular compartment-specific information ( Du et al., 2007 ; Hwang et al., 2010 ; van Gelderen et al., 2012 ; Sati et al., 2013 ). Similar to theT2-based method, the premise is that the myelin-associated water has a distinctly decreased stripin: si15.gif and that the exchange between the free and myelin water pools is slow enough to observe non-mono-exponential stripin: si16.gif decay as a function of echo time (TE) for myelin-containing tissue ( van Gelderen et al., 2012 ). Therefore, information about myelin water can also be gained from multi-component fitting of the stripin: si17.gif relaxation decay curve. Moreover, compared to mSE-based acquisition measurements, it has been reported that mGRE-based acquisition for mapping stripin: si18.gif provides higher contrast-to-noise ratio in structural MRI and BOLD fMRI ( Duyn et al., 2007 ) and lower radiofrequency power deposition at high magnetic field strengths. Another advantage of the three-component stripin: si19.gif model is that it provides frequency information, which improves the discrimination between myelin, axonal, and interstitial water due to their different frequency shifts ( van Gelderen et al., 2012 ; Sati et al., 2013 ). Therefore, in addition to demyelination, this model might provide new insights into axonal injury and degenerative processes.

The fitting of a three-component model to stripin: si20.gif decay curves acquired at 7 T was recently evaluated in healthy human brains ( Sati et al., 2013 ), but the feasibility of this technique in MS patients, and what it uncovers about lesion biology, remains to be demonstrated. For this purpose, mGRE data were acquired in cohort of MS patients at 7 T to investigate whether the fitting of a three-component model to the stripin: si21.gif decay curve can be used for characterizing demyelination in patient brains.

2. Materials and methods

2.1. Subjects

Twenty-five relapsing–remitting MS (RRMS) patients (6 men, 19 women; age range, 30–63 years; mean 41 years; standard deviation 8.4) were recruited from August 2013 to May 2014 under an Internal Review Board approved human protocol. Experienced MS clinicians determined disability according to the Expanded Disability Status Scale (EDSS) and obtained clinical data. Median EDSS score was 1.5 (range = 1–6.5) and mean disease duration was 8.5 years (range = 0.3–21.6 years).

2.2. MRI acquisition

All MRI examinations were performed on a 7 T human MRI scanner (Siemens, Erlangen, Germany) equipped with a 32-channel receive coil.

The mGRE data for mapping the stripin: si22.gif decay curves were acquired with an in-house developed pulse-sequence ( van Gelderen et al., 2012 ). Echo times (TEs) ranged from 2.3 to 62.7 ms. Thirty-eight echoes (positive read gradient only) were acquired with an echo spacing of 1.6 ms. Repetition time (TR) was 1 s and flip angle (FA) was 70°. Fifteen slices with 1.5 mm slice thickness and 25% gap between slices were measured per scan, with an in-plane resolution of 1.5 × 1.5 mm and a FOV of 240 × 180 mm (the acquisition matrix size is 160 × 120). The slices were parallel to the plane of the anterior and posterior commissure line and captured a section of the corpus callosum. Five signal averages were acquired within a total scan time of 10 min.

Whole brain 3DT1-weighted magnetization-prepared rapid gradient echo (T1-MPRAGE) was acquired before (pre-gadT1) and after (post-gadT1) contrast injection (0.1 mmol/kg gadobutrol; Bayer Healthcare, Leverkusen, Germany).

2.3. Imaging reconstruction and fitting of a three-component model to the stripin: si23.gif decay curves

All mGRE data analyses were performed in Interactive Data Language (IDL, Exelis Visual Information Solutions, Boulder, CO, USA).

The complex images were combined from individual receiver channels using unaccelerated (rate-1) SENSE reconstruction ( Pruessmann et al., 1999 ), then co-registered based on the fourth echo of the first repetition, since increased image contrast at this TE is expected to increase registration performance. The phase corrections before fitting consisted of two steps, one was a function of echo time, the other a spatial correction. Step one: in every voxel the average offset frequency was subtracted based on a linear fit (over TE) to the phase of the echoes, accounting for possible 2π wrapping jumps. Step two: for each echo time, a spatial linear phase was subtracted, that is for every image the global phase and the in-plane (spatial) gradients were taken out. The complex images were normalized to the smoothed magnitude image at first echo (TE = 2.3 ms). Smoothing was accomplished by Gaussian filtering over 30 voxels within a brain mask, excluding the skull and extracerebral cerebrospinal fluid, to preserve the contrast between lesions and their surrounding tissue. Normalization to a smoothed image was performed to remove both scan-to-scan variability and residual receive coil sensitivity effects, while preserving increased signal intensity in lesions due to their higher water content.

Using normalized stripin: si24.gif-weighted mGRE magnitude images (20th echo, TE = 33.6 ms), regions of interest (ROIs) were drawn manually in the splenium of the corpus callosum (SCC) ( Fig. 1 a) and the optic radiations (OR) ( Fig. 1b ), excluding visible lesions, to check the reproducibility of the fitting of the three-component model to the stripin: si25.gif decay curve. Furthermore, ROIs were chosen in all lesions visible on these stripin: si26.gif-weighted mGRE magnitude images (20th echo, TE = 33.6 ms) ( Fig. 2 a) for each scan. Lesions were identified by hyperintensity on these same normalized stripin: si27.gif-weighted mGRE magnitude images (20th echo, TE = 33.6 ms), because myelin decreases stripin: si28.gif and thus myelin loss leads to brighter intensity on the stripin: si29.gif-weighted image. In addition, control ROIs ( Fig. 2b , blue) were chosen in normal appearing white matter (NAWM) with a size and shape similar to the lesions. Any visible veins, which were low image intensity on stripin: si30.gif-weighted mGRE, were excluded from all the ROIs. Enhancing lesions were identified from post-gadT1-MPRAGE ( Fig. 3 c and f).

gr1

Fig. 1 Example of ROI selection for SCC (a) and OR (b). ROIs (green) were drawn manually on stripin: si1.gif-weighted mGRE magnitude images (20th echo with TE = 33.6 ms). The black arrow indicates a visible vein in right OR that was excluded from the ROI.

gr2

Fig. 2 Example ROI selection for MS lesion and its contralateral NAWM. Lesion (red rectangle) with a visible vein (black arrow) was identified on the normalized stripin: si2.gif-weighted mGRE (STE = 33.6) magnitude image (a). Lesion ROI (purple) and ROI in contralateral NAWM with matching geometry (blue) (b).

gr3

Fig. 3 Identification of two enhancing lesions. The lesions (red rectangle) appear on normalized pre-gad stripin: si3.gif-weighted mGRE magnitude (STE = 33.6) (a and d), pre-gad T1-weighted MPRAGE (b and e), as well as on post-gad T1-weighted MPRAGE (c and f).

Similarly to our previous study ( Sati et al., 2013 ), the ROI-averaged complex signalSwas calculated and fitted with a three-component model using the following equation.

FORMULA:

stripin: si31.gif

Here,Anis the amplitude,stripin: si32.gif is the relaxation time, and Δfnis the frequency shift of componentn, which is defined relative to global/interstitial water frequencyfg.φis the phase offset. Components 1, 2 and 3 were assigned to myelin, axonal and interstitial water respectively ( van Gelderen et al., 2012 ; Sati et al., 2013 ). Based on our preliminary data, the starting values for the fitting were defined asA1 = 0.16,A2 = 0.43,A3 = 0.41;stripin: si33.gif,stripin: si34.gif,stripin: si35.gif; Δf1 = 21 Hz, Δf2 = −6 Hz,fg = 0 Hz, andφ = 0 Hz. For the analyses of lesions, thestripin: si36.gif and Δf1were fixed at values from contralateral NAWM as the myelin water signal in lesions proved to be too small to determine these independently. A range of values was tested, which did not change the results significantly ( Supplementary table ).

2.3.4. Statistical analyses

Statistical analysis was carried out using a two-tailed Student's t-test to investigate differences between enhancing lesions and NAWM, non-enhancing lesions and NAWM, and enhancing versus non-enhancing lesions for the three-component fitting results. The significance threshold was taken asp < 0.05.

3. Results

Twelve enhancing lesions were detected in 7 patients, these appeared on both post-gadT1-MPRAGE and magnitude images. Sixty-one non-enhancing lesions were included in the study. Voxel-level image average SNR was approximately 200:1 in the first echo in the ROIs examined. The average size of lesions was 77.6 mm3(range 10.1–253.1 mm3) ( Table 1 ). In total, 25 ROIs in SCC and OR, as well as 73 lesions and their corresponding contralateral NAWM ROIs, were analyzed using the fitting of a three-component model to the stripin: si42.gif decay curve.

Table 1 Relevant parameters for ROIs used for fitting the three-component model to the stripin: si4.gif decay curve. Volume indicates ROI size, SNR the average signal-to-noise ratio of voxels within ROI. Goodness of fit is assessed both using 1-R2, where R2is the coefficient of determination, and the ratio of residue-to-noise, which refers to the difference between temporal standard deviation of the residue of the fitting and the actual noise level in the ROI-averaged signal. The results are shown as mean ± standard deviation (SD) overNROIs.

ROI N Volume (mm3) SNR 1-R2 (E−04) Ratio of residue/noise
SCC 25 800.4 ± 265.0 196.2 ± 16.8 0.8 ± 0.4 6.4 ± 1.9
OR 25 655.3 ± 242.0 229.2 ± 20.8 1.4 ± 0.5 9.4 ± 2.8
Enhancing lesion 12 111.4 ± 70.7 244.0 ± 63.0 1.5 ± 1.3 5.2 ± 3.6
Non-enhancing lesion 61 70.2 ± 55.7 224.9 ± 28.5 1.1 ± 1.1 3.0 ± 2.1
Contralateral NAWM 73 73.1 ± 54.7 224.1 ± 32.1 1.3 ± 1.0 2.6 ± 1.3

As seen in Fig. 4 and Table 1 , the model described the mGRE data. Goodness of fit was assessed using the 1-R2values, where R2is the coefficient of determination ( Colin Cameron and Windmeijer, 1997 ) and indicates how well the data fit the decay curve. AR2of 1 would indicate that the model perfectly fits the decay curve. All 1-R2values were lower than 0.001, which means that over 99.99% of the variance was explained using this model. The residues were further evaluated by comparing temporal standard deviation to the thermal noise level in the ROI-averaged signal. Note that this noise level varies notably from one ROI to the next, since it depends on the number of voxels averaged and thus on ROI size.

gr4

Fig. 4 Example of a three-compartment model fit to magnitude (a) and phase (b) of ROI-averaged signalS(see the equation) for lesion (red) and contralateral NAWM (blue). Measurement data (symbols) are well matched by the model fit (lines).

Results from the fitting of this three-component model for the different ROIs (SCC, OR, lesion and contralateral NAWM) are shown in Table 2 . The average amplitude of myelin water (A1) was 0.12 in SCC and 0.10 in both OR and NAWM, but only approximately 0.03 in lesions. As expected, the stripin: si43.gif of myelin water was the shortest, whereas the axonal water had the longest stripin: si44.gif. Myelin water showed the largest frequency shift (25.8 Hz in SCC), whereas that of axonal water was small and negative (−6.3 Hz in SCC). The frequency shift of myelin water was smaller in NAWM than in SCC and OR, presumably due to orientation effects.

Table 2 ROI-based fitting of a three-component model to the stripin: si5.gif decay curve for SCC, OR, lesion and normal-appearing white matter (NAWM).Anis the amplitude, stripin: si6.gif the relaxation time (ms), and Δfnthe frequency shift (Hz) of componentn. Mean values and the standard deviation (SD) overNROIs are shown.

ROI N   Myelin water Axonal water Interstitial water
  A 1 stripin: si7.gif (ms) Δf1 (Hz) A 2 stripin: si8.gif (ms) Δf2 (Hz) A 3 stripin: si9.gif (ms)
SCC 25 Mean 0.12 6.2 25.8 0.47 39.9 −6.3 0.36 30.2
SD 0.02 0.7 4.6 0.02 3.9 0.6 0.02 4.3
OR 25 Mean 0.10 6.7 22.5 0.49 31.2 −6.5 0.37 46.3
SD 0.02 0.7 5.2 0.06 1.8 0.7 0.04 9.5
Enhancing lesion 12 Mean 0.03 0.57 64.0 −3.1 0.40 56.0
SD 0.02 0.05 15.1 1.6 0.05 19.1
Non-enhancing lesion 61 Mean 0.04 0.57 63.0 −3.1 0.37 60.9
SD 0.02 0.05 38.4 1.0 0.04 24.9
Contralateral NAWM 73 Mean 0.10 7.6 13.3 0.53 36.0 −5.4 0.34 43.7
SD 0.02 1.7 9.3 0.04 3.6 0.9 0.04 9.7

In both enhancing and non-enhancing lesions, the amplitude of myelin water (A1) was found to be significantly decreased (ΔA1 ~ 0.07,p < 0.001) compared to contralateral NAWM. Since one would expect reductions inA1to be accompanied by increases in stripin: si45.gif and thus signal intensity (S) at longer echo times in the mGRE images, this relationship was investigated by generating a scatter plot ( Fig. 5 ) in which the fitted myelin water amplitude (A1) was plotted as a function of the signal intensity (S) in the normalized 20th echo (33.6 ms TE) mGRE magnitude image (STE = 33.6). Indeed, a significant correlation (R = 0.61,p < 0.001) and a negative slope (0.21) between the two parameters are seen, which appears dominated by the differences between lesions and NAWM.

gr5

Fig. 5 Relationship between fitted myelin water amplitude (A1) andSTE = 33.6. The red and blue points indicate lesions and NAWM respectively.

The axonal water amplitude (A2) was found to be increased in both enhancing lesions (ΔA2 = 0.04,p < 0.05) and non-enhancing lesions (ΔA2 = 0.04,p < 0.001) in comparison to NAWM. In the comparison of interstitial water amplitude (A3) between lesions and NAWM, the interstitial water amplitude (A3) in enhancing lesions increased 0.06 (p < 0.05) and in non-enhancing lesions only 0.03 (p < 0.001). The stripin: si46.gif values of axonal and interstitial water both showed a significant increase in lesions compared with NAWM (stripin: si47.gif,p < 0.001;stripin: si48.gif,p < 0.05). The Δfvalues were lower by ~2.3 Hz (p < 0.001) for axonal water in both enhancing and non-enhancing lesions when compared to NAWM. No significant difference between enhancing and non-enhancing lesions was found for any of the parameters studied, including the amplitudes of myelin, axonal, and interstitial water (A1,A2, andA3), the stripin: si49.gif values of interstitial and axonal water, or Δfof axonal water.

4. Discussion

In this exploratory study, we investigated the effects of demyelination on stripin: si50.gif relaxation in a clinical MS cohort at 7 T. Our 3-compartment model of white matter allowed reproducible fitting of the stripin: si51.gif decay curves, demonstrating the feasibility to detect and potentially discriminate demyelination in MS.

The results obtained here for ROIs in SCC are consistent with our previous study in healthy volunteers ( Sati et al., 2013 ), which confirm that stripin: si52.gif decay curves can be adequately described by a three-component model with distinct relaxation rates and frequency shifts for each component. Our average value for the amplitude of myelin water (A1) in SCC was around 0.12, which is also consistent with previous studies using bothT2-based ( Whittall et al., 1997 ; Vavasour et al., 1998 ; Laule et al., 2004 ) and stripin: si53.gif-based methods ( Du et al., 2007 ; Hwang et al., 2010 ). In addition, our average value for the myelin water amplitude measured in NAWM ROIs (around 0.10) is also similar to a previous report in healthy volunteers ( Hwang et al., 2010 ).

Our values for the multiple frequencies in SCC are also consistent with our previous results ( Sati et al., 2013 ) and with similar results from another group ( Wharton and Bowtell, 2013 ). As expected, the mean frequency shift is largest for the myelin water compartment ( Table 2 ) due to the perpendicular orientation of the SCC fibers relative the static B0magnetic field. Note that this myelin frequency shift is strongly dependent on the fiber orientation ( Lee et al., 2010 ; Sati et al., 2013 ; Duyn, 2014 ). Therefore, the NAWM ROIs used here, which in general contain a wider mix of fiber orientations, were expected to display a lower mean value and larger variation for the myelin water frequency shift when compared to the more directionally aligned fibers in SCC and OR ( Table 2 ). As NAWM in MS patients may harbor undetected pathology, the lower frequency shift of myelin water compared to healthy brain might be related to reductions in myelin as well.

In both types of lesion ROIs (enhancing and non-enhancing), our finding of a significant decrease in the amplitude of myelin water suggests ongoing demyelination in these lesions. Note that because the myelin water signal in the lesions was very small, the parametersstripin: si54.gif and Δf1were fixed to the reference values obtained from fitting of the contralateral NAWM ROIs. No significant change for fitting results while using different fixed values (supplementary table), which supports that taking the fixed parameters is not a major issue and not a cause for the small numbers of myelin water fraction. Interestingly, the standard deviation (SD) of myelin water amplitude was found to be around 0.02, which is quite large compared to the average myelin water amplitude in lesions but similar to the SD of the fitted myelin water amplitude in SCC and NAWM. This suggests that our estimate of the myelin water amplitudes is reasonable and probably could imply different degrees of demyelination in lesions, while the precision of these amplitude estimates is limited by sensitivity. At the same time, our estimate of the myelin water fraction in lesions is lower than found previously using aT2-based method ( Laule et al., 2004 ). This discrepancy could result from various factors, including methodological differences: for example, a loss of anisotropic susceptibility in the lesion could reduce the distinction between the water pools.

A positive correlation between total water amplitude andSTE = 33.6was found when combining data from both lesions and NAWM, which indicates that lesions have higher proton density and/or increased stripin: si55.gif due to more water than NAWM. However, this correlation was not apparent within the lesion group. It is possible that, in some of the lesions of the current patient cohort, the effects of myelin loss onSTE = 33.6are overwhelmed by the presence of CSF-like interstitial fluid with very long stripin: si56.gif as is sometimes seen in chronic lesions.

Our finding of a significant increase in the amplitude of both interstitial and axonal water compartments of the lesions is interpreted as water moving from between myelin layers to the extracellular and/or axonal compartments during the demyelination process. Myelin loss may cause relatively large changes in stripin: si57.gif because of the diamagnetic properties of myelin ( Stanisz et al., 1999 ), and because myelin compartmentalizes water and thereby reduces diffusion-mediated averaging of the associated magnetic field inhomogeneities. The frequency shifts of the three signal components are related to the myelin content. The separation of interstitial and axonal water in lesions is expected to be affected by the significantly reduced myelin content, which can lead to a reduced frequency offset between axonal and interstitial water that was expected ( Table 2 ). However, the similar SD of the fitted amplitudes of interstitial and axonal water in lesions when compared to SCC suggests that these components were separated fairly well within lesions.

Increased stripin: si58.gif was demonstrated to correspond to severe loss of myelin in comparisons of MRI with histology in MS lesions ( Yao et al., 2012 ; Lee et al., 2012 ). In our study, the stripin: si59.gif of interstitial and axonal water showed a significant increase in lesions compared to NAWM (around 27 and 12 ms respectively), which suggested myelin loss. Moreover, in MS lesions, Δfvalues were found to be smaller for axonal water relative to NAWM, consistent with myelin loss ( Yablonskiy et al., 2012 ).

We did not find any significant difference between enhancing and non-enhancing lesions for any of the compartmental amplitudes, for stripin: si60.gif of interstitial and axonal water, or for Δfof axonal water. If we assume that enhancement reflects an inflammatory process that accompanies ongoing demyelination, and thus that non-enhancing lesions may be more stable and/or partially remyelinated, one would expect this to be reflected in the stripin: si61.gif decay characteristics. However, the increased SDs of the component parameters in both enhancing and non-enhancing lesions compared to contralateral NAWM, suggest that the absence of significant correlation may be due to a large variation in demyelination within each lesion type, combined with the small number of enhancing lesions included in the analysis.

The fitting of a three-component model to the stripin: si62.gif decay curves, as was done here, has several limitations. First, aside from myelin, iron and protein content can also affect stripin: si63.gif decay ( Duyn et al., 2007 ), which was not accounted for. Second, the range of TEs in the current study (2.3 ms −62.7 ms) might be suboptimal for fitting long-T2components present in some lesion types. Third, using results from NAWM as reference values to fix thestripin: si64.gifand Δf1of the contralateral lesion may not be accurate, considering that NAWM can have abnormal myelin water amplitude as well ( Laule et al., 2004 ; Oh et al., 2007 ). This could in principle be mediated by using values from age- and sex-matched healthy volunteers, although accurate delineation of corresponding ROIs would be difficult. Finally, in absence of histopathological evidence, the precise relationship between the amplitude of the short stripin: si65.gif component and brain myelin content remains unclear.

5. Conclusions

In summary, fitting of a three-component model to the stripin: si66.gif decay curves at high magnetic field allows characterization of myelin water and detection of demyelination in MS. It also provides frequency information of axonal water, which may help to further characterize tissue damage in this disease. The experimental findings reported here are consistent with expectations based on prior radiological and pathological work and further strengthen the cases that analysis of stripin: si67.gif decay curves promises to have important consequences for understanding myelin pathology in MS and other neurological disorders.

The following is the supplementary data related to this article.

Download file

Supplementary table ROI-based fitting of a three-component model to the stripin: si68.gif decay curve for enhancing and non-enhancing lesions with different fixed myelin water stripin: si69.gif(stripin: si70.gif) and frequency shift (∆f1) values. Within a reasonable range, changing the fixed parameters only affects the myelin water amplitude.Anis the amplitude,stripin: si71.gif the relaxation time (ms), and ∆fnthe frequency shift (Hz) of componentn. Mean values (standard deviation) overNROIs are shown. *p < 0.05, significant difference between the fitting result showed in the table and result of the same lesion that was listed in Table 2 .

Acknowledgments

We thank the National Institute of Neurological Disorders and Stroke (NINDS) Neuroimmunology Clinic for coordinating the recruitment of human subjects. We acknowledge the NINDS Intramural Research Program for support, as well as the National Institutes of Health — Karolinska Institutet Graduate Programme for International PhDs.

References

  • Andrews et al. 2005 Andrews T., Lancaster J.L., Dodd S.J., Contreras-Sesvold C., Fox P.T. Testing the three-pool white matter model adapted for use with T2 relaxometry. Magn. Reson. Med.. 2005;54(2):449-454 10.1002/mrm.20599 16032666 Crossref
  • Colin Cameron, and Windmeijer 1997 Colin Cameron A., Windmeijer F.A.G. An R-squared measure of goodness of fit for some common nonlinear regression models. Journal of Econometrics. 1997;77(2):329-342 10.1016/S0304-4076(96)01818-0 Crossref
  • Du et al. 2007 Du Y.P., Chu R., Hwang D., Brown M.S., Kleinschmidt-DeMasters B.K., Singel D., Simon J.H. Fast multislice mapping of the myelin water fraction using multicompartment analysis of T2* decay at 3T: a preliminary postmortem study. Magn. Reson. Med.. 2007;58(5):865-870 10.1002/mrm.21409 17969125 Crossref
  • Duyn 2014 Duyn J.H. Frequency shifts in the myelin water compartment. Magn. Reson. Med.. 2014;71(6):1953-1955 10.1002/mrm.24983 24700549 Crossref
  • Duyn et al. 2007 Duyn J.H., van Gelderen P., Li T.-Q., de Zwart J.A., Koretsky A.P., Fukunaga M. High-field MRI of brain cortical substructure based on signal phase. Proc. Natl. Acad. Sci. U S A. 2007;104(28):11796-11801 10.1073/pnas.0610821104 17586684 Crossref
  • Hwang, Kim, and Du 2010 Hwang D., Kim D.-H., Du Y.P. In vivo multi-slice mapping of myelin water content using T2* decay. Neuroimage. 2010;52(1):198-204 10.1016/j.neuroimage.2010.04.023 20398770 Crossref
  • Lancaster et al. 2003 Lancaster J.L., Andrews T., Hardies L.J., Dodd S., Fox P.T. Three-pool model of white matter. J. Magn. Reson. Imaging. 2003;17(1):1-10 10.1002/jmri.10230 12500269 Crossref
  • Laule et al. 2008 Laule C., Kozlowski P., Leung E., Li D.K., Mackay A.L., Moore G.R. Myelin water imaging of multiple sclerosis at 7 T: correlations with histopathology. Neuroimage. 2008;40(4):1575-1580 10.1016/j.neuroimage.2007.12.008 18321730 Crossref
  • Laule et al. 2006 Laule C., Leung E., Lis D.K., Traboulsee A.L., Paty D.W., MacKay A.L., Moore G.R. Myelin water imaging in multiple sclerosis: quantitative correlations with histopathology. Mult. Scler.. 2006;12(6):747-753 10.1177/1352458506070928 17263002 Crossref
  • Laule et al. 2007 Laule C., Vavasour I.M., Kolind S.H., Li D.K., Traboulsee T.L., Moore G.R., MacKay A.L. Magnetic resonance imaging of myelin. Neurotherapeutics. 2007;4(3):460-484 10.1016/j.nurt.2007.05.004 17599712 Crossref
  • Laule et al. 2004 Laule C., Vavasour I.M., Moore G.R., Oger J., Li D.K., Paty D.W., MacKay A.L. Water content and myelin water fraction in multiple sclerosis. A T2 relaxation study. J. Neurol.. 2004;251(3):284-293 10.1007/s00415-004-0306-6 15015007 Crossref
  • Lee et al. 2010 Lee J., Shmueli K., Fukunaga M., van Gelderen P., Merkle H., Silva A.C., Duyn J.H. Sensitivity of MRI resonance frequency to the orientation of brain tissue microstructure. Proc. Natl. Acad. Sci. U S A. 2010;107(11):5130-5135 10.1073/pnas.0910222107 20202922 Crossref
  • Lee et al. 2012 Lee J., Shmueli K., Kang B.-T., Yao B., Fukunaga M., van Gelderen P., Palumbo S., Bosetti F., Silva A.C., Duyn J.H. The contribution of myelin to magnetic susceptibility-weighted contrasts in high-field MRI of the brain. Neuroimage. 2012;59(4):3967-3975 10.1016/j.neuroimage.2011.10.076 22056461 Crossref
  • MacKay et al. 2006 MacKay A., Laule C., Vavasour I., Bjarnason T., Kolind S., Mädler B. Insights into brain microstructure from the T2 distribution. Magn. Reson. Imaging. 2006;24(4):515-525 10.1016/j.mri.2005.12.037 16677958 Crossref
  • MacKay et al. 1994 MacKay A., Whittall K., Adler J., Li D., Paty D., Graeb D. In vivo visualization of myelin water in brain by magnetic resonance. Magn. Reson. Med.. 1994;31(6):673-677 10.1002/mrm.1910310614 8057820 Crossref
  • Moore et al. 2000 Moore G.R., Leung E., MacKay A.L., Vavasour I.M., Whittall K.P., Cover K.S., Li D.K., Hashimoto S.A., Oger J., Sprinkle T.J., Paty D.W. A pathology-MRI study of the short-T2 component in formalin-fixed multiple sclerosis brain. Neurology. 2000;55(10):1506-1510 10.1212/WNL.55.10.1506 11094105 Crossref
  • Oh et al. 2007 Oh J., Han E.T., Lee M.C., Nelson S.J., Pelletier D. Multislice brain myelin water fractions at 3 T in multiple sclerosis. J Neuroimaging. 2007;17(2):156-163 10.1111/j.1552-6569.2007.00098.x 17441837 Crossref
  • Pruessmann et al. 1999 Pruessmann K.P., Weiger M., Scheidegger M.B., Boesiger P. SENSE: sensitivity encoding for fast MRI. Magn. Reson. Med.. 1999;42(5):952-962 10542355 Crossref
  • Sati et al. 2013 Sati P., van Gelderen P., Silva A.C., Reich D.S., Merkle H., de Zwart J.A., Duyn J.H. Micro-compartment specific T2* relaxation in the brain. Neuroimage. 2013;77:268-278 10.1016/j.neuroimage.2013.03.005 23528924 Crossref
  • Stanisz et al. 1999 Stanisz G.J., Kecojevic A., Bronskill M.J., Henkelman R.M. Characterizing white matter with magnetization transfer and T(2). Magn. Reson. Med.. 1999;42(6):1128-1136 10.1002/(SICI)1522-2594(199912)42:6<1128::AID-MRM18>3.0.CO;2-9 10571935 Crossref
  • Van Gelderen et al. 2012 Van Gelderen P., de Zwart J.A., Lee J., Sati P., Reich D.S., Duyn J.H. Nonexponential stripin: si72.gif decay in white matter. Magn. Reson. Med.. 2012;67(1):110-117 10.1002/mrm.22990 21630352 Crossref
  • Vavasour et al. 1998 Vavasour I.M., Whittall K.P., MacKay A.L., Li D.K., Vorobeychik G., Paty D.W. A comparison between magnetization transfer ratios and myelin water percentages in normals and multiple sclerosis patients. Magn. Reson. Med.. 1998;40:763-768 Crossref
  • Wharton, and Bowtell 2013 Wharton S., Bowtell R. Gradient echo based fiber orientation mapping using R2* and frequency difference measurements. Neuroimage. 2013;83:1011-1023 10.1016/j.neuroimage.2013.07.054 23906549 Crossref
  • Whittall et al. 1997 Whittall K.P., MacKay A.L., Graeb D.A., Nugent R.A., Li D.K., Paty D.W. In vivo measurement of T2 distributions and water contents in normal human brain. Magn. Reson. Med.. 1997;37:34-43 Crossref
  • Yablonskiy et al. 2012 Yablonskiy D.A., Luo J., Sukstanskii A.L., Iyer A., Cross A.H. Biophysical mechanisms of MRI signal frequency contrast in multiple sclerosis. Proc. Natl. Acad. Sci. U S A. 2012;109(35):14212-14217 10.1073/pnas.1206037109 22891307 Crossref
  • Yao et al. 2012 Yao B., Bagnato F., Matsuura E., Merkle H., van Gelderen P., Cantor F.K., Duyn J.H. Chronic multiple sclerosis lesions: characterization with high-field-strength MR imaging. Radiology. 2012;262(1):206-215 10.1148/radiol.11110601 22084205 Crossref

Footnotes

a Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, MD 20892, USA

b Department of Neurobiology, Care Sciences and Society, Division of Clinical Geriatrics, Center for Alzheimer Disease Research, Karolinska Institutet, Stockholm SE-141 57, Sweden

c Translational Neuroradiology Unit, Division of Neuroimmunology and Neurovirology, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, MD 20892, USA

lowast Corresponding author at: Karolinska Institutet, Department of Neurobiology, Care Sciences and Society, Division of Clinical Geriatrics, Novum 5th floor, Blickagången 6, 141 57 Huddinge, Sweden. Tel.: +46 858585470; fax: +46 858585408.


Search this site

Stay up-to-date with our monthly e-alert

If you want to regularly receive information on what is happening in MS research sign up to our e-alert.

Subscribe »

About the Editors

  • Prof Timothy Vartanian

    Timothy Vartanian, Professor at the Brain and Mind Research Institute and the Department of Neurology, Weill Cornell Medical College, Cornell...
  • Dr Claire S. Riley

    Claire S. Riley, MD is an assistant attending neurologist and assistant professor of neurology in the Neurological Institute, Columbia University,...
  • Dr Rebecca Farber

    Rebecca Farber, MD is an attending neurologist and assistant professor of neurology at the Neurological Institute, Columbia University, in New...

This online Resource Centre has been made possible by a donation from EMD Serono, Inc., a business of Merck KGaA, Darmstadt, Germany.

Note that EMD Serono, Inc., has no editorial control or influence over the content of this Resource Centre. The Resource Centre and all content therein are subject to an independent editorial review.

The Grant for Multiple Sclerosis Innovation
supports promising translational research projects by academic researchers to improve understanding of multiple sclerosis (MS) for the ultimate benefit of patients.  For full information and application details, please click here

Journal Editor's choice

Recommended by Prof. Brenda Banwell

Causes of death among persons with multiple sclerosis

Gary R. Cutter, Jeffrey Zimmerman, Amber R. Salter, et al.

Multiple Sclerosis and Related Disorders, September 2015, Vol 4 Issue 5